Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
1.
Rev Sci Instrum ; 92(5): 053537, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243288

RESUMEN

A new pseudolocal tomography algorithm is developed for soft X-ray(SXR) imaging measurements of the turbulent electron temperature fluctuations (δ Te) in tokamaks and stellarators. The algorithm overcomes the constraints of limited viewing ports on the vessel wall (viewing angle) and limited number of lines of sight (LOS). This is accomplished by increasing the number of LOS locally in a region of interest. Numerical modeling demonstrates that the wavenumber spectrum of the turbulence can be reliably reconstructed, with an acceptable number of viewing angles and LOS and suitable low SNR detectors. We conclude that a SXR imaging diagnostic for measurements of turbulent δ Te using a pseudolocal reconstruction algorithm is feasible.

2.
Proc Biol Sci ; 286(1908): 20190745, 2019 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-31362632

RESUMEN

Functional diversity is an important aspect of biodiversity, but its relationship to species diversity in time and space is poorly understood. Here we compare spatial patterns of functional and taxonomic diversity across marine and terrestrial systems to identify commonalities in their respective ecological and evolutionary drivers. We placed species-level ecological traits into comparable multi-dimensional frameworks for two model systems, marine bivalves and terrestrial birds, and used global species-occurrence data to examine the distribution of functional diversity with latitude and longitude. In both systems, tropical faunas show high total functional richness (FR) but low functional evenness (FE) (i.e. the tropics contain a highly skewed distribution of species among functional groups). Functional groups that persist toward the poles become more uniform in species richness, such that FR declines and FE rises with latitude in both systems. Temperate assemblages are more functionally even than tropical assemblages subsampled to temperate levels of species richness, suggesting that high species richness in the tropics reflects a high degree of ecological specialization within a few functional groups and/or factors that favour high recent speciation or reduced extinction rates in those groups.


Asunto(s)
Biodiversidad , Aves , Bivalvos , Ecosistema , Animales , Geografía , Modelos Biológicos
4.
Rev Sci Instrum ; 89(5): 053503, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29864849

RESUMEN

A newly upgraded correlation electron cyclotron emission (CECE) diagnostic has been installed on the ASDEX Upgrade tokamak and has begun to perform experimental measurements of electron temperature fluctuations. CECE diagnostics measure small amplitude electron temperature fluctuations by correlating closely spaced heterodyne radiometer channels. This upgrade expanded the system from six channels to thirty, allowing simultaneous measurement of fluctuation level radial profiles without repeat discharges, as well as opening up the possibility of measuring radial turbulent correlation lengths. Newly refined statistical techniques have been developed in order to accurately analyze the fluctuation data collected from the CECE system. This paper presents the hardware upgrades for this system and the analysis techniques used to interpret the raw data, as well as measurements of fluctuation spectra and fluctuation level radial profiles.

5.
Phys Rev Lett ; 120(7): 075001, 2018 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-29542943

RESUMEN

A long-standing enigma in plasma transport has been resolved by modeling of cold-pulse experiments conducted on the Alcator C-Mod tokamak. Controlled edge cooling of fusion plasmas triggers core electron heating on time scales faster than an energy confinement time, which has long been interpreted as strong evidence of nonlocal transport. This Letter shows that the steady-state profiles, the cold-pulse rise time, and disappearance at higher density as measured in these experiments are successfully captured by a recent local quasilinear turbulent transport model, demonstrating that the existence of nonlocal transport phenomena is not necessary for explaining the behavior and time scales of cold-pulse experiments in tokamak plasmas.

6.
Rev Sci Instrum ; 89(1): 013504, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29390665

RESUMEN

Recent attempts to measure impurity transport in Alcator C-Mod using an x-ray imaging crystal spectrometer and laser blow-off impurity injector have failed to yield unique reconstructions of the transport coefficient profiles. This paper presents a fast, linearized model which was constructed to estimate diagnostic requirements for impurity transport experiments. The analysis shows that the spectroscopic diagnostics on Alcator C-Mod should be capable of inferring simple profiles of impurity diffusion DZ and convection VZ accurate to better than ±10% uncertainty, suggesting that the failure to infer unique DZ and VZ from experimental data is attributable to an inadequate analysis procedure rather than the result of insufficient diagnostics. Furthermore, the analysis reveals that even a modest spatial resolution can overcome a low time resolution. This approach can be adapted to design and verify diagnostics for transport experiments on any magnetic confinement device.

7.
Rev Sci Instrum ; 87(11): 11E102, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910478

RESUMEN

Turbulent temperature fluctuations are measured on the ASDEX Upgrade tokamak using pairs of closely spaced, narrow-band heterodyne radiometer channels and a standard correlation technique. The pre-detection spacing and bandwidth of the radiometer channel pairs is chosen such that they are physically separated less than a turbulent correlation length, but do not overlap. The radiometer has 4 fixed filter frequency channels and two tunable filter channels for added flexibility in the measurement position. Relative temperature fluctuation amplitudes are observed in a helium plasma to be δT/T = (0.76 ± 0.02)%, (0.67 ± 0.02)%, and (0.59 ± 0.03)% at normalised toroidal flux radius of ρtor = 0.82, 0.75, and 0.68, respectively.

8.
Int J Obes (Lond) ; 40(12): 1856-1863, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27534842

RESUMEN

BACKGROUND/OBJECTIVES: Androgen deprivation therapy (ADT) is commonly used for treatment of prostate cancer but is associated with side effects, such as sarcopenia and insulin resistance. The role of lifestyle factors such as diet and exercise on insulin sensitivity and body composition in testosterone-deficient males is poorly understood. The aim of the present study was to examine the relationships between androgen status, diet and insulin sensitivity. SUBJECTS/METHODS: Middle-aged (11-12 years old) intact and orchidectomized male rhesus macaques were maintained for 2 months on a standard chow diet and then exposed for 6 months to a Western-style, high-fat/calorie-dense diet (WSD) followed by 4 months of caloric restriction (CR). Body composition, insulin sensitivity, physical activity, serum cytokine levels and adipose biopsies were evaluated before and after each dietary intervention. RESULTS: Both intact and orchidectomized animals gained similar proportions of body fat, developed visceral and subcutaneous adipocyte hypertrophy and became insulin resistant in response to the WSD. CR reduced body fat in both groups but reversed insulin resistance only in intact animals. Orchidectomized animals displayed progressive sarcopenia, which persisted after the switch to CR. Androgen deficiency was associated with increased levels of interleukin-6 and macrophage-derived chemokine (C-C motif chemokine ligand 22), both of which were elevated during CR. Physical activity levels showed a negative correlation with body fat and insulin sensitivity. CONCLUSIONS: Androgen deficiency exacerbated the negative metabolic side effects of the WSD such that CR alone was not sufficient to improve altered insulin sensitivity, suggesting that ADT patients will require additional interventions to reverse insulin resistance and sarcopenia.


Asunto(s)
Andrógenos/deficiencia , Composición Corporal/fisiología , Hipogonadismo/patología , Resistencia a la Insulina/fisiología , Obesidad/patología , Andrógenos/fisiología , Animales , Restricción Calórica , Dieta Alta en Grasa , Modelos Animales de Enfermedad , Interleucina-6 , Lípidos , Macaca mulatta , Masculino , Condicionamiento Físico Animal , Receptores Androgénicos
9.
Rev Sci Instrum ; 87(2): 023502, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26931844

RESUMEN

Recent analysis of Gas Puff Imaging (GPI) data from Alcator C-Mod found blob velocities with a modified tracking time delay estimation (TDE). These results disagree with velocity analysis performed using direct Fourier methods. In this paper, the two analysis methods are compared. The implementations of these methods are explained, and direct comparisons using the same GPI data sets are presented to highlight the discrepancies in measured velocities. In order to understand the discrepancies, we present a code that generates synthetic sequences of images that mimic features of the experimental GPI images, with user-specified input values for structure (blob) size and velocity. This allows quantitative comparison of the TDE and Fourier analysis methods, which reveals their strengths and weaknesses. We found that the methods agree for structures of any size as long as all structures move at the same velocity and disagree when there is significant nonlinear dispersion or when structures appear to move in opposite directions. Direct Fourier methods used to extract poloidal velocities give incorrect results when there is a significant radial velocity component and are subject to the barber pole effect. Tracking TDE techniques give incorrect velocity measurements when there are features moving at significantly different speeds or in different directions within the same field of view. Finally, we discuss the limitations and appropriate use of each of methods and applications to the relationship between blob size and velocity.

10.
Rev Sci Instrum ; 85(11): 11D811, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25430224

RESUMEN

A tunable correlation electron cyclotron (CECE) system was recently installed on the Alcator C-Mod tokamak to provide local, quantitative measurement of electron temperature fluctuations in the tokamak core. This system represents a significant upgrade from the original CECE system, expanding the measurement capabilities from 4 to 8 total channels, including 2 remotely tunable YIG filters (6-18 GHz; 200 MHz bandwidth). Additional upgrades were made to the optical system to provide enhanced poloidal resolution and allow for measurement of turbulent fluctuations below kθρs < 0.3. These expanded capabilities allow for single shot measurement of partial temperature fluctuation profiles in the region ρ = 0.7 - 0.9 (square root of normalized toroidal flux) in a wide variety of plasma conditions. These measurements are currently being used to provide stringent tests of the gyrokinetic model in ongoing model validation efforts. Details of the hardware upgrades, turbulent fluctuation measurements, and ongoing comparisons with simulations are presented.

11.
Thromb Haemost ; 111(3): 539-48, 2014 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-24258486

RESUMEN

Vasodilator-stimulated phosphoprotein (VASP) is phosphorylated and dephosphorylated consequent to increases and decreases in cyclic nucleotide levels. Monitoring changes in VASP phosphorylation is an established method for indirect measurement of cyclic nucleotides. Here we describe the use of an innovative cocktail, VASPFix, which allows sensitive and reproducible measurement of phosphorylated VASP (VASP-P) in a simple, single-step procedure using cytometric bead technology. Frozen VASPFix-treated samples are stable for at least six months prior to analysis. We successfully used VASPFix to measure VASP-P in platelets in both platelet-rich plasma and blood in response to compounds that increase (dibutyryl cAMP, adenosine, iloprost, PGE1) and decrease (ADP, PGE1) cAMP, and to determine the effects of certain receptor antagonists on the results obtained. The change in VASP-P brought about by adding ADP to PGE1-stimulated platelets is a combination of the effect of ADP at the P2Y12 receptor and of PGE1 at both IP and EP3 receptors. For iloprost-stimulated platelets EP3 receptors are not involved. A procedure in which iloprost, ADP and VASPFix were used to determine effectiveness of clopidogrel and prasugrel in patients was compared with an established commercial procedure that uses PGE1 and ADP; the latter produced higher platelet reactivity values that were the result of PGE1 interacting with platelet EP3 receptors. We conclude that VASPFix can be used both as a research tool and for clinical investigations and provides better specificity for P2Y12 receptor inhibition. The latter confers a distinct advantage over existing methods used to monitor effects of P2Y12 antagonists on platelet function.


Asunto(s)
Biomarcadores Farmacológicos/metabolismo , Plaquetas/efectos de los fármacos , Moléculas de Adhesión Celular/metabolismo , AMP Cíclico/metabolismo , Proteínas de Microfilamentos/metabolismo , Fosfoproteínas/metabolismo , Pruebas de Función Plaquetaria/métodos , Trombofilia/diagnóstico , Trombofilia/tratamiento farmacológico , Adenosina/metabolismo , Adenosina Difosfato/metabolismo , Alprostadil/metabolismo , Plaquetas/fisiología , Bucladesina/metabolismo , Células Cultivadas , Clopidogrel , Humanos , Iloprost/metabolismo , Fosforilación/efectos de los fármacos , Piperazinas/administración & dosificación , Agregación Plaquetaria/efectos de los fármacos , Clorhidrato de Prasugrel , Antagonistas del Receptor Purinérgico P2Y/administración & dosificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tiofenos/administración & dosificación , Ticlopidina/administración & dosificación , Ticlopidina/análogos & derivados
12.
Phys Rev Lett ; 111(5): 055005, 2013 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-23952414

RESUMEN

The effect of small deviations from a Maxwellian equilibrium on turbulent momentum transport in tokamak plasmas is considered. These non-Maxwellian features, arising from diamagnetic effects, introduce a strong dependence of the radial flux of cocurrent toroidal angular momentum on collisionality: As the plasma goes from nearly collisionless to weakly collisional, the flux reverses direction from radially inward to outward. This indicates a collisionality-dependent transition from peaked to hollow rotation profiles, consistent with experimental observations of intrinsic rotation.

13.
Phys Rev Lett ; 110(4): 045003, 2013 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-25166172

RESUMEN

A critical gradient threshold has been observed for the first time in a systematic, controlled experiment for a locally measured turbulent quantity in the core of a confined high-temperature plasma. In an experiment in the DIII-D tokamak where L(T(e))(-1) = |∇T(e)|/T(e) and toroidal rotation were varied, long wavelength (k(θ)ρ(s) ≲ 0.4) electron temperature fluctuations exhibit a threshold in L(T(e))(-1): below, they change little; above, they steadily increase. The increase in δT(e)/T(e) is concurrent with increased electron heat flux and transport stiffness. Observations were insensitive to rotation. Accumulated evidence strongly enforces the identification of the experimentally observed threshold with ∇T(e)-driven trapped electron mode turbulence.

14.
Rev Sci Instrum ; 83(11): 113504, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23206059

RESUMEN

This research describes advancements in the spectral analysis and error propagation techniques associated with x-ray imaging crystal spectroscopy (XICS) that have enabled this diagnostic to be used to accurately constrain particle, momentum, and heat transport studies in a tokamak for the first time. Doppler tomography techniques have been extended to include propagation of statistical uncertainty due to photon noise, the effect of non-uniform instrumental broadening as well as flux surface variations in impurity density. These methods have been deployed as a suite of modeling and analysis tools, written in interactive data language (IDL) and designed for general use on tokamaks. Its application to the Alcator C-Mod XICS is discussed, along with novel spectral and spatial calibration techniques. Example ion temperature and radial electric field profiles from recent I-mode plasmas are shown, and the impact of poloidally asymmetric impurity density and natural line broadening is discussed in the context of the planned ITER x-ray crystal spectrometer.

15.
Rev Sci Instrum ; 83(10): 10E301, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126961

RESUMEN

The two-color interferometry diagnostic on the Alcator C-Mod tokamak has been upgraded to measure fluctuations in the electron density and density gradient for turbulence and transport studies. Diagnostic features and capabilities are described. In differential mode, fast phase demodulation electronics detect the relative phase change between ten adjacent, radially-separated (ΔR = 1.2 cm, adjustable), vertical-viewing chords, which allows for measurement of the line-integrated electron density gradient. The system can be configured to detect the absolute phase shift of each chord by comparison to a local oscillator, measuring the line-integrated density. Each chord is sensitive to density fluctuations with k(R) < 20.3 cm(-1) and is digitized at up to 10 MS/s, resolving aspects of ion temperature gradient-driven modes and other long-wavelength turbulence. Data from C-Mod discharges is presented, including observations of the quasi-coherent mode in enhanced D-alpha H-mode plasmas and the weakly coherent mode in I-mode.

16.
Rev Sci Instrum ; 83(10): 10E311, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23126971

RESUMEN

A correlation electron cyclotron emission (CECE) diagnostic has been installed in Alcator C-Mod. In order to measure electron temperature fluctuations, this diagnostic uses a spectral decorrelation technique. Constraints obtained with nonlinear gyrokinetic simulations guided the design of the optical system and receiver. The CECE diagnostic is designed to measure temperature fluctuations which have k(θ) ≤ 4.8 cm(-1) (k(θ)ρ(s) < 0.5) using a well-focused beam pattern. Because the CECE diagnostic is a dedicated turbulence diagnostic, the optical system is also flexible, which allows for various collimating lenses and antenna to be used. The system overview and the demonstration of its operability as designed are presented in this paper.

18.
Diabetologia ; 54(6): 1480-90, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21400042

RESUMEN

AIMS: Hypoxia has been implicated as a cause of adipose tissue inflammation in obesity, although the inflammatory response of human adipose tissue to hypoxia is not well understood. The goal of this study was to define in vitro inflammatory responses of human adipose tissue to hypoxia and identify molecular mechanisms of hypoxia-induced inflammation. METHODS: The inflammatory milieu and responses of visceral (VAT) and subcutaneous (SAT) adipose tissue explants and purified stromovascular cells (SVFs) from obese and lean humans were studied in an in vitro hypoxic culture system using quantitative real-time PCR, ELISA, western blotting, immunofluorescence microscopy, flow cytometry and immunohistochemistry. RESULTS: Human adipose tissue in obesity demonstrates an increased leucocyte infiltrate that is greater in VAT than SAT and involves macrophages, T cells and natural killer (NK) cells. Hypoxic culture regulates inflammatory cytokine secretion and transcription of metabolic stress response genes in human adipose tissue SVF. Adipocyte diameter is increased and adipose tissue capillary density is decreased in obese participants. Inhibition of c-Jun terminal kinase (JNK) or p38 significantly attenuates hypoxia-induced SVF inflammatory responses. Hypoxia induces phosphorylation of p38 in adipose tissue. CONCLUSIONS: Human adipose tissue in obesity is characterised by a depot-specific inflammatory cell infiltrate that involves not only macrophages, but also T cells and NK cells. Hypoxia induces inflammatory cytokine secretion by human adipose tissue SVF, the primary source of which is adipose tissue macrophages. These data implicate p38 in the regulation of hypoxia-induced inflammation and suggest that alterations in adipocyte diameter and adipose tissue capillary density may be potential underlying causes of adipose tissue hypoxia.


Asunto(s)
Citocinas/metabolismo , Hipoxia/fisiopatología , Grasa Intraabdominal/metabolismo , Obesidad/metabolismo , Grasa Subcutánea/metabolismo , Delgadez/metabolismo , Adulto , Células Cultivadas , Femenino , Humanos , Grasa Intraabdominal/patología , Células Asesinas Naturales/patología , MAP Quinasa Quinasa 4/metabolismo , Macrófagos/patología , Masculino , Persona de Mediana Edad , Obesidad/patología , Fosforilación , Grasa Subcutánea/patología , Linfocitos T/patología , Delgadez/patología , Proteínas Quinasas p38 Activadas por Mitógenos/metabolismo
19.
Rev Sci Instrum ; 81(10): 10D907, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033939

RESUMEN

A novel multichannel, tunable Doppler backscattering (DBS)/reflectometry system has recently been developed and applied to a variety of DIII-D plasmas. Either DBS or reflectometry can be easily configured for use in a wide range of plasma conditions using a flexible quasi-optical antenna system. The multiple closely spaced channels, when combined with other fluctuation diagnostic systems, have opened up new measurements of plasma properties. For example, the toroidal and fine-scale radial structure of coherent plasma oscillations, such as geodesic acoustic modes, have been probed simultaneously in the core of high temperature plasmas by applying correlation analysis between two toroidally separated DBS systems, as well as within the multichannel array. When configured as a reflectometer, cross-correlation with electron cyclotron emission radiometry has uncovered detailed information regarding the crossphase relationship between density and temperature fluctuations. The density-temperature crossphase measurement yields insight into the physics of tokamak turbulence at a fundamental level that can be directly compared with predictions from nonlinear gyrokinetic simulations.

20.
Rev Sci Instrum ; 81(10): 10D912, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21033944

RESUMEN

The quasioptical design of a new integrated Doppler backscattering (DBS) and correlation electron cyclotron emission (CECE) system is presented. The design provides for simultaneous measurements of intermediate wavenumber density and long wavelength electron temperature turbulence behavior. The Doppler backscattering technique is sensitive to plasma turbulence flow and has been utilized to determine radial electric field, geodesic acoustic modes, zonal flows, and intermediate scale (k∼1-6 cm(-1)) density turbulence. The correlation ECE system measures a second turbulent field, electron temperature fluctuations, and is sensitive to long poloidal wavelength (k≤1.8 cm(-1)). The integrated system utilizes a newly installed in-vessel focusing mirror that produces a beam waist diameter of 3.5-5 cm in the plasma depending on the frequency. A single antenna (i.e., monostatic operation) is used for both launch and receive. The DBS wavenumber is selected via an adjustable launch angle and variable probing frequency. Due to the unique system design both positive and negative wavenumbers can be obtained, with a range of low to intermediate wavenumbers possible (approximately -3 to 10 cm(-1)). A unique feature of the design is the ability to place the DBS and CECE measurements at the same radial and poloidal locations allowing for cross correlation studies (e.g., measurement of nT cross-phase).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA